To effectively predict insulator contamination levels
improve operational safety and reliability of catenary
an on-line monitoring catenary insulator leakage current device is developed
which is based on ARM. The device judges whether insulators should be cleaned by the contamination levels
which is predicted by leakage current and ambient humidity. Select a composite insulators of FQBJ—25 /8—760P as research object
carry out artificial pollution test using on-line monitoring device
under satur-ated air humidity. Fitting relation curves of contamination level and leakage current using experimental datas
and provide guidance to confirm alarm value of catenary insulator leakage current on-line monitoring device. Based on three-stage idea of pollution flashover
propose safe operating area
filth cleaning area and danger area of catenary insulator.