基于心阻抗法的无创心功能检测技术具有重要的临床应用价值。首先简述了心阻抗法检测的基本原理
然后对近年来国内外的相关研究和应用进展进行综述。通过对检测中在胸腔建模、电极配置、临床应用等方面存在的问题进行比较深入的总结和探讨。
The technology of non-invasive heart function detection based on impedance cardiography is of great value in clinical applications.The basic principle of impedance cardiography detection is firstly introduced
then summarizes the latest related studies and application status at home and abroad.Relatively profound summaries and discussions in terms of thoracic modeling
electrode configuration and clinical application are made.
无创血液动力学监测对高血压治疗的影响 [J]. 钟传茂,许德饶,刘俊德. 中国医疗前沿 . 2011(11)
基于电阻抗法无拘束心排量检测的最佳电极配置 [J]. 宋义林,高树枚,五十岚朗,山越宪一. 生物医学工程学杂志 . 2011(01)
无创心脏血流动力学监测仪的工作原理、参数意义和临床价值 [J]. 马立业. 中国心血管杂志 . 2008(01)
人体细胞内外液分布阻抗测量仪的研究 [J]. 彭承琳,郭兴明. 仪器仪表学报 . 1996(06)
基于心电与阻抗信息的心血管功能检测研究 [D]. 胡鑫. 天津大学 2007
Impedance cardiographic hemodynamic variables and hypertension in elderly Han residents [J] . Zhao Xiajuan,Ding Ding,Huang Yanyan,Hong Zhen. Upsala Journal of Medical Sciences . 2013 (2)
Hemodynamic alterations in hypertensive patients at rest and during passive head-up tilt [J] . Antti J. Tikkakoski,Anna M. Tahvanainen,Miia H. Leskinen,Jenni K. Koskela,Antti Haring,Jani Viitala,Mika A.P. K?h?nen,Tiit K??bi,Onni Niemel?,Jukka T. Mustonen,Ilkka H. P?rsti. Journal of Hypertension . 2013 (5)
A portable device to assess underwater changes of cardio dynamic variables by impedance cardiography [J] . F Tocco,A Crisafulli,E Marongiu,R Milia,A Kalb,A Concu. Journal of Physics: Conference Series . 2012 (1)
Hemodynamic evaluation in pregnancy: limitations of impedance cardiography [J] . Manfred G Moertl,Dietmar Schlembach,Ilona Papousek,Helmut Hinghofer-Szalkay,Elisabeth M Weiss,Uwe Lang,Helmut K Lackner. Physiological Measurement . 2012 (6)
Hemodynamic changes during pregnancy and postpartum: a prospective study using thoracic electrical bioimpedance [J] . Luis San-Frutos,Virginia Engels,Ignacio Zapardiel,Tirso Perez-Medina,Jose Almagro-Martinez,Rafael Fernandez,Jose M. Bajo-Arenas. Journal of Maternal-Fetal and Neonatal Medicine . 2011 (11)
Comparison of a three‐quarter electrode band configuration with a full electrode band configuration for impedance cardiography [J] . Simon L.Bacon,Avril J.Keller,Kim L.Lavoie,Tavis S.Campbell. Psychophysiology . 2010 (6)
Comparison of band and spot electrodes for the measurement of stroke volume by the bioelectric impedance technique [J] . ROBERT W. GOTSHALL,WILLIAM R. SEXSON. Critical Care Medicine . 1994 (3)
Simplified electrode array for impedance cardiography [J] . B. C. Penney,N. A. Patwardhan,H. B. Wheeler. Medical & Biological Engineering & Computing . 1985 (1)