LIU Gang1, LIANG Ting1, HUAN Tao1, et al. Design on gas chamber of reflective infrared methane sensor[J]. 2013, 32(2): 96-98. DOI: 10.13873/j.1000-97872013.02.044.
a kind of chamber design process and test results of reflective infrared methane sensor which has good stability and high sensitivity are put forward.Infrared methane sensor is based on the principle of dispersion type infrared absorption spectroscopy;non-dispersive infrared(NDIR) detection technology is applied to get infrared of methane characteristics wavelength
then dual channel compensation technology is used to test volume fraction of methane in gas chamber.Chamber is composed of infrared detector
transmission optical way
infrared source integrated assembly
whose structure and performance are important for device.Inner wall of chamber is designed as paraboloid of revolution with Au film coating
and infrared is reflected to be approximately parallel light
which is reflected to detector while propagating in chamber
so as to increase absorption optical path of methane
and sensitivity of chamber is improved.After completing the design
methane environment test shows that performance such as stability
sensitivity
reaction time of reflective chamber are excellent.