WU Wen-rong1, YU Da-hai1, QIU Zu-rong2, et al. Development of semi-automatic micro-assembly system for millimeter device[J]. 2013, 32(1): 83-86+90. DOI: 10.13873/j.1000-97872013.01.014.
Micro-target is an important device for inertial confinement fusion(ICF)research.A semi-automatic micro-assembly system is developed
which can be used to assemble micro inertial confinement fusion(ICF)target which is made up of two half-hohlraum(diameter range 800 -1 000 μm
length is about 1 mm)and a capsule(diameter range 200 -500 μm).Structure and compostion of the system is described
and the key technology and solution is introduced.The effect factors and mathematic model of online measuring system error for assembling process is analyzed.The results of target assembly experiments show that the precision of this system is not more than 10 μm.