基于光电传感器的血清与血细胞分层面的检测
摘要
根据生物医学检测中
离心后血液样本分层面位置检测的问题
提出了一种基于近红外光电传感器的无交叉污染的检测方法和装置。分析了在一定的波长范围内
单色光对于血清与血细胞的透过率和分层面检测方法的原理
阐述了该光电检测装置的结构和测试过程。经实验和数据分析
结果表明:该光电检测方法简单实用
稳定性能好
检测精度达到0.3 mm
完全达到了自动分样分层面识别的要求
为全自动样本前处理系统的研制提供了重要的保障。
Abstract
To solve the problem induced by detection for interface of the blood samples in the field of medical detection
a detection method and equipment which based on the optoelectronic senor are presented
which voided cross-contamination when detected.The penetrate rate of the serum and blood cells and the principle of detecting method are analyzed under the specific wave length range.The structure and measurement process of the detection method and equipment are given.According to the experiment data
the method is easy and practical
also has a good stability
the precision is 0.3mm and totally meets the aquirements of automatic detection the interface in the process of sub-sample systems.