浙江大学流体传动及控制国家重点实验室
纸质出版:2011
移动端阅览
[1]阮晓东,巴静,陈晖,陈文昱,傅新.基于PVDF薄膜的流场动态压力检测方法的研究[J].传感器与微系统,2011,30(07):51-53+56.
RUAN Xiao-dong, BA Jing, CHEN Hui, et al. Study on dynamic pressure detection method for flow field based on PVDF film[J]. 2011, 30(7): 51-53+56.
[1]阮晓东,巴静,陈晖,陈文昱,傅新.基于PVDF薄膜的流场动态压力检测方法的研究[J].传感器与微系统,2011,30(07):51-53+56. DOI: 10.13873/j.1000-97872011.07.038.
RUAN Xiao-dong, BA Jing, CHEN Hui, et al. Study on dynamic pressure detection method for flow field based on PVDF film[J]. 2011, 30(7): 51-53+56. DOI: 10.13873/j.1000-97872011.07.038.
针对检测狭小空间流场压力时
通用液体压力传感器存在体积大、频响低以及干扰流场等问题
提出一种基于聚偏氟乙烯(PVDF)薄膜的流场动态压力检测方法
该方法采用光刻工艺直接在敷镀有金属铝电极的PVDF薄膜上制作压力传感元件
该元件具有面积小、厚度薄、柔韧性好的特点
非常适合于狭小流场空间壁面压力分布的测量。试验研究表明:该方法特别适用于检测流场微小的压力波动
线性度误差为±2.3%
输出灵敏度为1.32mV/Pa。
Aiming at the problems of large size
low frequency response and arousing disturbance to the flow field that most present liquid pressure sensors have when detecting flow field pressure of narrow space
a PVDF film-based flow field dynamic pressure detection method is proposed.Directly fabricated from an aluminum-coated PVDF film using lithographic process
the sensing element implemented in this method has been endowed with the advantages of small size
thin thickness and good flexibility
which make it applicable for the wall pressure distribution measurement for narrow gap flow field.Experimental research shows that this method is well suitable for the slight pressure fluctuation detection in the flow field
with a linearity error of ±2.3% and a sensitivity of 1.32mV/Pa.
轴向柱塞泵/马达技术的发展演变 [J]. 杨华勇,张斌,徐兵. 机械工程学报 . 2008(10)
滑动轴承非线性动态油膜压力分布特性的研究 [J]. 杨金福,杨昆,于达仁,杨勇平,付忠广,刘占生. 动力工程 . 2005(04)
柱塞泵阻尼槽噪声特性研究 [J]. 冀宏,傅新,杨华勇,王庆丰. 浙江大学学报(工学版) . 2005(05)
PVDF多点脉搏波计算机辅助测试系统研究 [J]. 金观昌,于淼,鲍乃铿. 清华大学学报(自然科学版) . 1999(08)
Impeller Behavior and Displacement of the VentrAssist Implantable Rotary Blood Pump [J] . Michael K.H.Chung,NongZhang,Geoff D.Tansley,John C.Woodard. Artificial Organs . 2004 (3)
Investigations of the Temperature Behaviour of the Piston Cylinder Assembly in Axial Piston Pumps [J] . Lars Olems. International Journal of Fluid Power . 2000 (1)
New noninvasive piezoelectric transducer for recording of respiration, heart rate and body movements [J] . J. Siivola. Medical & Biological Engineering & Computing . 1989 (4)
0
浏览量
205
下载量
1
CSCD
关联资源
相关文章
相关作者
相关机构