Operational parameters are decided only by experience in traditional electronic nose experiment methods
which can’t make sure the experiments’ repetition and the maximum efficiency.So the design of experiment is introduced to experiment of electronic nose.Central composite design is used to ascertain the experimental point quickly
and for the target of the biggest fuzzy corrected synthetic response
key parameters of preconcentration-electronic nose system is optimized.Theory analysis and experimental result show that the optimization method conductes to repetitious experiment of electronic nose
and which can obtain the maximum experimental information for the minimal experimental cost.
关键词
Keywords
references
Diagnostic potential of breath analysis—focus on volatile organic compounds [J] . Wolfram Miekisch,Jochen K Schubert,Gabriele F.E Noeldge-Schomburg. Clinica Chimica Acta . 2004 (1)
Optimisation of electronic nose measurements. Part II: Influence of experimental parameters [J] . Sylvie Roussel,Gustaf Forsberg,Pierre Grenier,Véronique Bellon-Maurel. Journal of Food Engineering . 1999 (1)
Analyzing organic vapors in exhaled breath using a surface acoustic wave sensor array with preconcentration: Selection and characterization of the preconcentrator adsorbent [J] . William A Groves,Edward T Zellers,Gregory C Frye. Analytica Chimica Acta . 1998 (2)