CHEN Shou-qiang, XIAO Rong-chuan, XIAO Ji-xue. Research on signal processing in power smart sensor[J]. 2008, 27(11): 38-40+43. DOI: 10.13873/j.1000-97872008.11.019.
Application of error least mean square(LMS)method in voltage testing of power smart sensor is exploited.Several ways to obtain voltage RMB and initial phase angle
which are important power parameters but difficult to test in power smart sensor
are proposed
analyzed and compared.It is pointed out that when error LMS method is applied
the performance requirement can be declined and results in system simplified and cost reduced.Simulation results show that sample frequency and ratio of signal to noise are required very high to got power parameters according to their definition directly
however
if error LMS method is applied
the sample frequency can be declined triple when obtaining voltage RMB