研制一种NO传感针并将其应用归经实验的在体测量中。以壳聚糖与Ni2+形成的配合物作为敏感膜
浸涂在微铂丝制成的基体电极上
再修饰Nafion膜层;在中医穴位归经实验中
用此传感针测定小鼠穴位和穴位旁开的两检测点在刺激前后的NO浓度。测定结果显示
线性范围为10-6
1
0-4mol/L
R2=0.9848;重复性误差为4.72%;平均回收率为97.74%;归经实验中
NO电流值在刺激前后穴位都明显高于穴位旁开时(P
<
0.05)该NO传感针的选择性好、稳定性高、重复性好
其针状结构可适用于在体测量。在体实验结果表明:存在穴位特异性
并证实了经脉的循经性
为循经传感理论提供了实际的技术支持。
A kind of NO sensor is developed
and it is used in the vivo measurement of meridian experiments.The nitric oxide sensor is made of the pure platinum wire modified by the chitosan and Ni2+ solution and decorated by the Nafion membranes from its surface.This sensor is used to measure the nitric oxide concentration of the acupoints and non-acupoints before and after acupuncture in the rats.The linear response range of this sensor is 10-6
1
0-4mol/L with the square of the correlation coefficient 0.9848.Reproducibility is 4.72%
average recovery is 97.74%
in the experiments of meridian
the current of NO in the acupoints is obviously higher than in the non-acupoints(P
<
0.05).Its selectivity
s
tability and repeatability are good and its pintype structure is applicable to vivo measurement.The results in vivo experiments of the rats show that there is the specificity in the acupoints and suggest that there is the existence of meridian specificity
so this sensor can provide a support in the technology for the theory of the meridian and acupoint.
生物体内一氧化氮的检测方法及其应用 [J]. 定天明,陈坚,张正行,张奕华. 药学进展 . 2005(05)
在体测量的新型氧分压传感针的研制及应用 [J]. 陈胜利,马长清,胡文慧,任霞,孔鄂生,任恕. 传感器技术 . 2005(05)
化学传感器在针灸经络研究中的应用及展望 [J]. 尹飞,郭义,徐放明. 天津中医药 . 2004(02)
一氧化氮的生理功能及浓度测定 [J]. 张聿高,伦秀英. 化学教学 . 2000(05)
走向新世纪的明星分子—NO [J]. 叶名文. 生物学教学 . 1999(12)
Nafion修饰铂电极电化学还原法测定溶液中的一氧化氮 [J]. 朱芳,莫金垣,蔡沛祥. 分析试验室 . 1999(04)
微型一氧化氮电流传感器的研制和应用 [J]. 陈刚,张剑霞,陆巍,赵鹏,程介士. 上海医科大学学报 . 1998(06)
一氧化氮标准溶液发生器 [P]. 毛兰群,田玉,鲜跃仲,徐琦. 中国专利:CN2288173,