a hand eye calibration method for selective compliance assembly robot arm( SCARA) robot plane assembly task is proposed. In this method
the output error of linear calibration method is reduced by iterations. Compared with the linear calibration method for hand eye calibration
the average positioning error of visual positioning is reduced by 0. 4 mm after calibration
and the maximum localization error is decreased by 0. 6 mm. When using SCARA robot for millimeter range operation
the hand eye calibration method using iterations has higher visual positioning accuracy than the traditional linear calibration method. At the same time
after the completion of the end effector to grasping tasks
pose end assembly using SCARA robot is proposed to solve the linear equations for the solution