1. 贵州中烟工业有限责任公司
2. 中国科学院合肥物质科学研究院应用技术研究所
纸质出版:2017
移动端阅览
[1]胡世龙,赵树弥,周磊,赖东辉,蒋惠智,张龙.滤棒压降的快速检测分选系统设计[J].传感器与微系统,2017,36(11):86-89.
HU Shi-long, ZHAO Shu-mi, ZHOU Lei, et al. Design of system of rapid detection and separation of pressure drop of filter rod[J]. 2017, 36(11): 86-89.
[1]胡世龙,赵树弥,周磊,赖东辉,蒋惠智,张龙.滤棒压降的快速检测分选系统设计[J].传感器与微系统,2017,36(11):86-89. DOI: 10.13873/j.1000-9787(2017)11-0086-04.
HU Shi-long, ZHAO Shu-mi, ZHOU Lei, et al. Design of system of rapid detection and separation of pressure drop of filter rod[J]. 2017, 36(11): 86-89. DOI: 10.13873/j.1000-9787(2017)11-0086-04.
为缩短滤棒压降检测分选时间
降低实验人员劳动强度
设计了一种自动化程度高的滤棒压降快速测量分选方法及实验装置。装置采用满足烟草行业新标准技术要求的双通道测量头实现并行检测
流程操控以可编程逻辑控制器(PLC)技术集中控制气路替代复杂的电控部件。集成嵌入式单片机(MCU)芯片和高速ADS8341数据采集芯片实现精密压降传感器信号采集
并计算分析滤棒压降值的分选属性。以双路分选臂实现双通道测量结果的快速分选。实验选用不同标称值的标准滤棒测试装置的精度与重复性
以不同阻值的滤棒进行实验测试
结果表明:装置测量速度超过了600支/h
较单测量头的速度提升了1倍
且不需人工参与。标准棒降压测试精度达到了10 Pa
不同滤棒分选的准确率达到了100%
满足实验检测要求。
In order to shorten time of detection and separation of filter rod pressure drop and lower experimenter’s labor intensity
a fast measurement and separation method of filter rod pressure drop is proposed and the automatic operation device is developed also. A measuring head with two measuring channels which meets the technical requirements of the new standard in the tobacco industry is designed for fast testing. The programmable logic controller( PLC) technology is used to control the gas path to replace the complicated electronic control parts.The value of high-precision pressure drop sensor and the filter rod pressure drop value are calculated and analyzed by both embedded micro-programmed control unit( MCU) chip and high-speed ADS8341 data acquisition chip. Two channels sorting arm are used to separate the dual channel measurement results. The accuracy and repeatability of the device are tested by the standard filter rods with different nominal values. The performance of the device is verified by the filter rods with different resistance values. The results show that the measurement speed of device is more than 600 filter rods per hour without manual operation
and is two times faster than a single measuring head device. The testing accuracy of the standard rod reached 10 Pa and the accuracy rate of different filter rods separating is up to 100 %
which meets the requirements of the experiment detection.
基于STM32F103的无主机通信系统的设计 [J]. 缪竟鸿,王薇,武志刚,韩信. 科学技术与工程 . 2017(04)
基于PLC的双余度海底管道开孔机远程电气控制系统设计 [J]. 许振腾,李艳军,曹愈远,王国超,乔磊,赵苏阳,汪雷. 科学技术与工程 . 2015(20)
基于ADS8341与ARM的数据采集模块接口设计 [J]. 韩卫洁,陈江锋,董兴,田军. 现代电子技术 . 2014(24)
综合测试台中吸阻/压降测量单元的优化改进 [J]. 代秀迎,吴超,赵战辉,李学恭,李彦辉. 烟草科技 . 2014(08)
烟草专用标准恒流孔的研究[J]. 蒋志才,苏中地,韩彬,尹招琴,丁雪,方婷. 计量学报. 2013 (02)
综合测试台在滤棒吸阻检测中的应用研究 [J]. 伊恒伟. 安徽农业科学 . 2013(05)
全自动烟支物理参数检测及其控制系统设计 [J]. 王施恩,梁杰申. 传感器与微系统 . 2011(02)
新一代嵌入式微处理器STM32F103开发与应用 [J]. 孙书鹰,陈志佳,寇超. 微计算机应用 . 2010(12)
基于DSP的卷烟吸阻测量仪自动分拣装置开发 [J]. 张吉卫,王旭光,张建军. 仪表技术与传感器 . 2009(04)
GB/T 22838.5-2009. 卷烟和滤棒物理性能的测定 第5部分:卷烟吸阻和滤棒压降 [S]. 2009
0
浏览量
33
下载量
1
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621