JIA Menghuan, TUO Xianguo, SHEN Tong, et al. Design of micro-seismic signal rapid identification system based on FPGA[J]. 2021, (3): 99-101+105. DOI: 10.13873/J.1000-9787(2021)03-0099-03.
High sampling rate microseismic data acquisition can improve the time resolution of microseismic data
but it also increases data redundancy. By embedding the FIR filter and STA/LTA algorithm inside the field programmable gate array( FPGA) core way to achieve continuous data acquisition for identifying microseismic data
reducing the spatially continuous noise data acquisition process invalid occupied. The research results show that the design system can quickly identify thue vibration data. Processing data of 1 s at a sampling rate of 100 k Hz requires only 2. 12 ms. At the same time
compared with the system without the vibration data identification
In 24 h test
the amount of data is reduced by about 72 %
which greatly reduces the pressure of data storage and transmission.