ZHOU Yiren, HE Risheng, Lü Qing. Design of pendulum type open channel flow measurement system based on ARM[J]. 2020, (10): 83-86. DOI: 10.13873/J.1000-9787(2020)10-0083-04.
基于ARM的摆杆式明渠测流系统设计
摘要
针对水利方面明渠测流过程中测量精度差
测流过程及数据处理繁琐等问题
设计了一种新型的摆杆式明渠测流系统。以ARM处理器为核心
传感器主要包括超声波模块、倾角监测模块。同时为了提高系统实时性
软件方面搭载了μC/OSⅢ操作系统与emWin图形库。系统测流时
先收集处理各传感器数据
再利用公式得到流量
并将数据显示在液晶屏上
同时数据会自动保存并上传。实验结果表明:与传统的明渠测流装置相比
该系统极大地提高了在明渠测流方面的准确性与实时性
也极大地简化了测流过程
提高了测流效率。
Abstract
Aiming at the problems of poor measurement precision
complicated flow measurement and data processing in open channel
a new type of swing bar type open channel flow measurement system is designed. The system takes ARM processor as the core
and the sensor mainly includes ultrasonic module and inclination monitoring module. Meanwhile
in order to improve the real-time performance of the system
the software is also equipped with μC/OSⅢ real-time operating system and em Win graphics library. When the system measures the flow
first the data of each sensor is collected and processed
then the system obtains the flow through the formula
and displays the data on the LCD screen. Meanwhile
the data will be saved and uploaded automatically. The experimental results show that compared with the traditional open channel flow measuring device
the system greatly improves the accuracy and real-time performance in the open channel flow measurement
and greatly simplifies the flow measurement process and improves the flow measurement efficiency.