[1]陈鹏,涂亚庆,杨辉跃,陈竹,罗毅,朱超.差分式科氏流量计测量原理和零点不稳定及补偿分析[J].传感器与微系统,2017,36(01):61-63+70.
CHEN Peng, TU Ya-qing, YANG Hui-yue, et al. Analysis on measurement principle and instability and compensation of zero point for differential Coriolis mass flowmeter[J]. 2017, 36(1): 61-63+70.
[1]陈鹏,涂亚庆,杨辉跃,陈竹,罗毅,朱超.差分式科氏流量计测量原理和零点不稳定及补偿分析[J].传感器与微系统,2017,36(01):61-63+70. DOI: 10.13873/J.1000-9787(2017)01-0061-03.
CHEN Peng, TU Ya-qing, YANG Hui-yue, et al. Analysis on measurement principle and instability and compensation of zero point for differential Coriolis mass flowmeter[J]. 2017, 36(1): 61-63+70. DOI: 10.13873/J.1000-9787(2017)01-0061-03.
针对差分式科氏流量计零点不稳定的问题
通过对一次仪表进行建模
分析其测量原理
分析了造成零点不稳定的原因。根据理论分析及实际调试经验
提出了零点补偿措施建议
有利于提升零点稳定性
减少测量误差
提高测量精度。
Aiming at zero point instability problems of differential Coriolis mass flowmeter
measuring principle is analyzed by modeling on primary instrument
and the reason results in instability of zero point is analyzed. The suggestion of zero point compensation measures is put forward by theoretical analysis and practical experience
which is helpful to enhance stability of zero point
reduce measurement error and improve measurement precision.
微流量计量方法的探讨 [J]. 李紫璇,王彦程. 化工管理 . 2015(11)
不同类型血液透析机的超滤系统原理及其应用 [J]. 应滋栋,张飞鸿,赵丽萍. 中国医学装备 . 2014(03)
超声波流量计静水时差温度漂移的解决方法 [J]. 李文博,袁涛. 传感器与微系统 . 2013(12)
检测科氏流量计振动管管壁附加物、磨损或腐蚀的方法和装置 [P]. 任建新,张忠洋,刘景峰,张鹏,熊亮. 中国专利:CN102012251A,
Numerical analysis of installation effects in Coriolis flowmeters: Single and twin tube configurations [J] . G. Bobovnik,J. Kutin,N. Mole,B. ?tok,I. Bajsi?. Flow Measurement and Instrumentation . 2015
Coriolis flowmeters: a review of developments over the past 20 years, and an assessment of the state of the art and likely future directions [J] . Tao Wang,Roger Baker. Flow Measurement and Instrumentation . 2014
Advances in Signal Acquisition and Signal Processing of Coriolis Flow Meters [J] . J. Ruoff,W. Gauchel,H. Kück. Procedia Engineering . 2014
Experimental investigation of zero phase shift effects for Coriolis flowmeters due to pipe imperfections [J] . Stephanie Enz,Jon Juel Thomsen,Stefan Neumeyer. Flow Measurement and Instrumentation . 2010 (1)
0
浏览量
51
下载量
8
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621