针对传统电子血压计不具备压力检定和校准功能的缺点
研制具有校准功能的电子血压计
通过改进血压计的气路结构实现压力的检定和自校准。测量实验中
静压的最大示值误差为2.1 mm Hg
血压为120/80的收缩压和舒张压重复性分别为3.00 mm Hg和1.716 mm Hg
血压为110/75的收缩压和舒张压的重复性分别为3.8 mm Hg和1.716 mm Hg;校准实验中
校准后的静压最大示值误差为0.7 mm Hg
收缩压和舒张压的平均差为1 mm Hg和-1 mm Hg、标准差为2 mm Hg和1.47 mm Hg。结果表明:样机满足JJG692—2010《无创自动测量血压计检定规程》的要求
校准后的样机可重新准确测量静压和血压并且准确度得到提高。
In view of shortcomings of traditional electric blood pressure meter that does not has functions of pressure verification and calibration
develop electric blood pressure meter with calibration function which can complete pressure verification and self-calibration by improving gas path structure of blood pressure meter. In experiment
the maximum error of static pressure is 2. 1 mm Hg
repeatability of systolic pressure is 3. 0 mm Hg
repeatability of diastolic pressure is 1. 716 mm Hg when blood pressure is 120 /80; repeatability of systolic pressure is 3. 8 mm Hg and repeatability of diastolic pressure is 1. 716 mm Hg when the blood pressure is 110 /75. In calibration experiment
the maximum error of static pressure after calibration is 0. 7 mm Hg
mean difference of systolic pressure and diastolic pressure are 1mm Hg and- 1 mm Hg
standard deviation of systolic pressure and diastolic pressure are 2 mm Hg and 1. 47 mm Hg. Results show that the prototype meets the requirements of JJG692—2010‘verification regulation of non-invasive blood pressure meter ’
the prototype after calibration can accurately measure static pressure and blood pressure
and the accuracy is improved.
基于压力传感器的高精度血压计系统设计 [J]. 胡锦,彭诗瑶,张浩,阎跃鹏. 传感器与微系统 . 2014(03)
便携式血液净化装置参数校准仪的研制 [J]. 金亮冰,李东升,陈爱军. 传感器与微系统 . 2013(04)
基于示波法的电子血压计系统设计 [J]. 刘坚强,王永才. 单片机与嵌入式系统应用 . 2010(04)
自校准电子水平仪的设计与实现 [J]. 潘雪,高国伟,王超,赵瑜,张军. 传感器与微系统 . 2008(01)
便携式电子血压计设计 [J]. 包旭鹤. 现代电子技术 . 2007(08)
基于示波法的数字血压计的硬件实现 [J]. 张晓芳,王剑钢. 仪器仪表用户 . 2006(04)
手指血压计的研制 [J]. 周云波,林家瑞. 传感器技术 . 1997(03)
JJG 692-2010. 无创自动测量血压计 [S]. 1999
0
浏览量
138
下载量
1
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621