LI Kai, CAI Chen, ZHAO Zhen-gang, et al. Design of variable sensitivity liquid level sensor for FBG[J]. 2016, 35(3): 121-123. DOI: 10.13873/J.1000-9787(2016)03-0121-03.
In order to achieve level of variable sensitivity monitoring is designed using a fiber Bragg grating( FBG) with variable sensitivity level probe. Liquid pressure on film is transmitted to cantilever beam through pressure bar
FBG is pasted on upper surface of cantilever beam
using sensitivity shift valve to change cantilever length
so as to change sensitivity of sensor. Calculated deformation properties of the cantilever beam by finite element simulation and optimization. The length of cantilever beam are adjusted to 100 mm
90 mm
80 mm. In all the above-mentioned states
the maximum deformation occurs in the tip of cantilever beam
which are 4. 266
3. 457
2. 736 mm respectively. Corresponding where bare grating pasted