1. 宁波大学机械工程与力学学院
2. 宁波戴维医疗器械股份有限公司
纸质出版:2016
移动端阅览
[1]魏威,柯沪琦,胡燕海.基于STM32的手持式测氧仪设计[J].传感器与微系统,2016,35(03):74-76.
WEI Wei, KE Hu-qi, HU Yan-hai. Design of handheld oxygen analyzer based on STM32[J]. 2016, 35(3): 74-76.
[1]魏威,柯沪琦,胡燕海.基于STM32的手持式测氧仪设计[J].传感器与微系统,2016,35(03):74-76. DOI: 10.13873/J.1000-9787(2016)03-0074-03.
WEI Wei, KE Hu-qi, HU Yan-hai. Design of handheld oxygen analyzer based on STM32[J]. 2016, 35(3): 74-76. DOI: 10.13873/J.1000-9787(2016)03-0074-03.
针对国内传统手持式测氧仪精度低、功耗高的问题
提出了采用嵌入式微控制器STM32F103RBT6作为控制芯片的手持式测氧仪。该仪器通过控制元器件的开断来降低待机功耗
根据所测浓度人工切换系统放大倍数
通过键盘设置时间和报警值等相关参数。算法上采用中位值平均滤波算法进行软件滤波
结合传统两点标定法和多点标定法的优缺点
采用多点标定法进行氧浓度标定
采用分段斜率拟合算法计算氧浓度值。经实验测试证明设计的手持测氧仪具有高精度和高稳定性。
Aiming at problem of low precision and high power consumption of domestic traditional handheld oxygen analyzer
an oxygen analyzer that adopts embedded microcontroller STM32F103RBT6 as control chip is put forward. Standby power consumption can be reduced by controlling opening and breaking of components
system magnification can be manually switched according to measured concentration
time and alarm value and other related parameters are set through keyboard. The median average filtering algorithm is used to carry out software filtering in algorithm
combined with advantages and disadvantages of traditional two-point calibration method and multi-point calibration method
use multi-point calibration method to realize calibration of oxygen concentration
oxygen concentration value is calculated by using piecewise slope fitting algorithm. Experimental test proves high precision and high stability of this design.
便携式医疗电子仪器设计中的MCU选型分析 [J]. 刘梦星,叶树明,许志,陈杭. 中国医疗器械杂志 . 2014(03)
便携式二氧化碳检测仪的设计 [J]. 闻明,张策. 传感器与微系统 . 2011(07)
基于单片机的多功能测氧仪设计 [J]. 王伟,董爱华. 仪表技术 . 2010(10)
传感器系统的二点标定新方法及其分析 [J]. 余学锋,于杰. 电子测量技术 . 2008(04)
智能氧化锆测氧仪的研究与设计 [D]. 黄睿. 武汉科技大学 2006