LAN Zhang-li, LAN Tian-feng, LU Yun-ping. Cable force measurement system based on elastic deformation[J]. 2015, 34(1): 88-90+93. DOI: 10.13873/J.1000-9787(2015)01-0088-03.
基于弹性形变的拉索索力测量系统
摘要
结合位移传感器
提出了基于弹性形变的拉索索力测量装置和方法
介绍了系统的结构和原理
通过标定、加载试验和滤波获得拉索索力数据和与之对应的拉索形变量数据。最后
经过数据拟合分析得出拉索形变量与拉索索力值的线性关系
并加以验证。当索力测量范围为5
2
0 k N
测量频率为1 Hz时
最大测量误差将可控制在10%以内
平均测量误差约5%
且随着待测索力的增大
测量精度随之升高。
Abstract
Combining with displacement sensor
measuring device and method of cable force based on elastic deformation is proposed; introduce structure and principle of the system; and then obtain datas of cable force and cable variable which are corresponding to cable force datas through calibration
loading experinment and filtering;finally
through data fitting analysis
obtain linear relationship between cable shaped variables and values of the cable force
at the same time
it is validated. When cable force measurement range of 5
20 k N and measurement frequency is 1 Hz
the maximum measurement error will be controlled within 10 %
average error of measurement is about 5 %
and with increasing of cable force measurement under test