基于固体电解质的电化学传感器可以在高温条件下实时、原位地检测气体组成。固体电解质和电极材质的不同会直接影响传感器的灵敏度、选择性以及响应时间。根据测量原理的不同
固体电解质基CH4电化学传感器通常分为电流型CH4传感器和电势型CH4传感器
对这两类传感器进行了详细的介绍
并对固体电解质基CH4电化学传感器在海底火山、热液喷口区等高温高压极端环境的研究与应用进行了展望。
Electrochemical sensor based on solid electrolyte are suitable for gas composition detection in situ and real time at high temperature. Difference of solid electrolyte and electrode material can directly affect sensitivity
selectivity and response time of sensor. According to difference of measuring principles
solid electrolyte based CH4electrochemical sensors are classified as amperometric and potentiometric CH4sensors
and these two types of sensors are described in detail
prospects of research and application of solid electrolyte based electrochemical sensors for detection of CH4in submarine volcanoes and hydrothermal vents at high temperature and high pressure are also discussed.
Study on mode-filtered light sensor for methane detection [J]. Martin M.F.Choi. Chinese Chemical Letters . 2009(02)
大气甲烷的源和汇与土壤氧化 (吸收 )甲烷研究进展 [J]. 王琛瑞,黄国宏,梁战备,吴杰,徐国强,岳进,史奕. 应用生态学报 . 2002(12)
Solid-state amperometric CH 4 sensor using, LaGaO 3 -based electrolyte [J] . Zhonghe Bi,Hiroshige Matsumoto,Tatsumi Ishihara. Solid State Ionics . 2007 (27)
Fast infrared spectrometer for flowing gases by the use of a hollow fiber and a PtSi sensor array [J] . M. Saito,T. Kato. Infrared Physics and Technology . 2005 (1)
Characteristics of an HC sensor using a Pr 6 O 11 electrode [J] . Tadashi Inaba,Keiichi Saji,Jiro Sakata. Sensors & Actuators: B. Chemical . 2005 (1)
Undoped and 0.1 wt.% Ca-doped Pt-catalyzed SnO 2 sensors for CH 4 detection [J] . Bong-Ki Min,Soon-Don Choi. Sensors & Actuators: B. Chemical . 2005 (1)
Electrochemical solid electrolyte gas sensors — hydrocarbon and NO x analysis in exhaust gases [J] . U. Guth,J. Zosel. Ionics . 2004 (5)
Methane sensitivity of Fe-doped SnO 2 thick films [J] . S. Bose,S. Chakraborty,B.K. Ghosh,D. Das,A. Sen,H.S. Maiti. Sensors & Actuators: B. Chemical . 2004 (2)
Response behavior of perovskites and Au/oxide composites as HC-electrodes in different combustibles [J] . J. Zosel,R. Müller,V. Vashook,U. Guth. Solid State Ionics . 2004 (1)
Investigation of a new catalytic combustion-type CH 4 gas sensor with low power consumption [J] . Liangyan Sun,Fabin Qiu,Baofu Quan. Sensors & Actuators: B. Chemical . 2000 (1)
A limiting current type sensor for hydrocarbons [J] . Y Eguchi,S Watanabe,N Kubota,T Takeuchi,T Ishihara,Y Takita. Sensors & Actuators: B. Chemical . 2000 (1)
Multi-electrode zirconia electrolyte amperometric sensors [J] . Solid State Ionics . 2000
A novel sensor for C1–C8 hydrocarbons using two zirconia-based electrochemical cells [J] . Takashi Hibino,Shuqiang Wang. Sensors & Actuators: B. Chemical . 1999 (1)
A parallel analysis of oxygen and combustibles in solid electrolyte amperometric cells [J] . S.I. Somov,U. Guth. Sensors & Actuators: B. Chemical . 1998 (1)
Gas microsensors using cyclic voltammetry with a cermet electrochemical cell [J] . E.L. Shoemaker,M.C. Vogt,F.J. Dudek,T. Turner. Sensors & Actuators: B. Chemical . 1997 (1)
Solid electrolyte HC sensor on gasoline engines [J] . T Hibino,Y Kuwahara,Y Kuroki,T Oshima,R Inoue,S Kitanoya,T Fuma. Solid State Ionics . 1997 (1)
Modelling and sensing characteristics of an amperometric hydrocarbon sensor [J] . Y. Tan,T.C. Tan. Chemical Engineering Science . 1996 (16)